A host clock is not synchronized to its time source
Separate time-source configuration, connectivity, client selection, and verification.
Read-only knowledge base · No public comments
Recognize the symptoms
A lab time client reports that its clock is unsynchronized, or two hosts’ logs disagree enough to obscure one event. A configured time source may still be unreachable or unselected. Record the time, identity, and client state before changing the clock.
Understand the likely causes
- A displayed time zone can differ without an actual clock offset. Network policy may block the source, the client may reject it, or the peers may not support the intended trust configuration. No single observation establishes the cause without correlating client and path evidence.
Capture the clock context
Record UTC time, the displayed offset or time zone, synchronization state, configured sources, and selected source for each affected host. Use the installed client’s supported status and log tools, since implementations expose different fields. Note when each reading was taken: comparing two sequential outputs does not yield an exact network-independent offset. Preserve the original configuration and avoid printing private hostnames or credentials into a shared report.
Separate network path and client acceptance
Check whether the intended source is reachable under the approved network policy and whether client logs show an accepted exchange or a rejection. A route to the server does not prove that the time protocol succeeds, and a received response does not prove the client selected a trusted source. Compare the client’s configuration, source identity, and any applicable authentication settings. Test from the same host and network context as the affected client.
Correct one confirmed cause
Reproduce the issue with a disposable lab client and approved test source. If the evidence identifies an incorrect source or policy, make only the authorized correction and retain the previous configuration and rollback procedure. Clock changes can affect certificates, applications, and logs, so follow the platform’s documented maintenance process instead of forcing an arbitrary step. Do not weaken authentication merely to make the status appear synchronized.
Verify source and application outcome
After the approved correction, inspect fresh client state and confirm that the intended source is selected and synchronization has been established according to that implementation. Compare a new cross-host event with explicit UTC timestamps and record the remaining uncertainty. Repeat the original certificate or log-correlation operation where appropriate. Preserve the earlier evidence and configuration so the result and any rollback can be reviewed without assuming an immediate perfect clock.
Verify the fix
Verify synchronization and the selected source, repeat the original operation, and compare fresh UTC timestamps while documenting measurement limits.
Keep it from recurring
- Document trusted time sources, ownership, and network policy; monitor client state and test source changes and recovery in a lab before production maintenance.