Prometheus / Editorial solution guide

An alert fires but no notification arrives

Trace an alert from rule evaluation through Alertmanager routing, suppression and receiver delivery using synthetic events.

About 3 min readContent reviewed

Read-only knowledge base ยท No public comments

Recognize the symptoms

A rule appears to be firing in Prometheus, but the expected receiver has no notification. Another alert may reach the receiver successfully. Record the safe alert name, labels, evaluation time, configured Alertmanager destination and receiver identifier without copying secrets or sending real production notifications.

Understand the likely causes

  • The rule may still be pending, Prometheus may not send to the intended Alertmanager, or routing labels may select another receiver. Grouping delays, silences and inhibition can also affect notification timing. A receiver integration or network failure can occur after routing, so a firing state alone does not prove delivery.

1. Verify the rule state

In an isolated fixture, evaluate a synthetic alert at fixed times before and after its configured pending duration. Inspect the expression result, alert labels and state in Prometheus; distinguish pending from firing and verify the expected series is present. Record the rule and evaluation interval. Do not weaken the production threshold or send a real page merely to reproduce the issue.

2. Trace Prometheus to Alertmanager

Check the configured Alertmanager destination and safe delivery errors, then inspect whether the synthetic alert appears in the intended Alertmanager instance. Compare the alert labels after any configured external labels or relabeling with the route matchers. Confirm the installed versions and effective configuration; a local rule test does not establish network delivery or receiver availability.

3. Inspect routing and suppression

Follow the matching route and receiver selection in a controlled configuration. Inspect grouping and configured wait intervals, active silences and inhibition rules for the synthetic labels. Use a harmless test receiver and compare an alert that should be suppressed with one that should pass. Do not remove broad silences or disable inhibition in production without identifying the intended operational policy.

4. Repair and verify the narrow boundary

Correct the rule, destination, route, suppression policy or receiver integration identified by the evidence. Validate configuration with the tools appropriate to the installed version and use the reviewed deployment procedure. Repeat the synthetic alert through firing, routing and the test receiver, then test recovery and a deliberately suppressed case. Record which network and receiver boundaries were actually exercised; avoid logging webhook credentials.

Verify the fix

Verify firing state, arrival at the intended Alertmanager, selected route and harmless receiver delivery with synthetic labels. Confirm suppression and recovery cases separately; a firing state is not delivery evidence.

Keep it from recurring

  • Maintain a tested notification path, safe routing fixtures and documented ownership for receivers and silences. Monitor delivery failures without exposing receiver credentials.

Official references